Hi,
I have defined some unit of measure in bus objects, using the bus editor, but whenever I run a simulation I get the following message:
Warning: The units 'm3' specified on block 'Controls/Engine Control Module/ECM model variant/ Internal ECM' are not defined in the Simulink
unit database. Investigate <b>52 similar inconsistencies</b> on Model Advisor Report.
If you cannot use a unit that exists in the database, consider suppressing all units inconsistency warnings by setting the configuration parameter
<sldiag objui="configset" objparam="UnitsInconsistencyMsg">'Units inconsistency messages'</sldiag> to 'none'.
I know this is the wrong way to define m3, and the correct way is m*m*m, but I need to define it like this to have another software correctly reading the unit when importing the simulation outputs from Simulink.
I'm using MATLAB R2017b and I could not find a way to set the Units incosistency messages to 'none'. How is this done?
NOTE:-
Matlabsolutions.com provide latest MatLab Homework Help,MatLab Assignment Help , Finance Assignment Help for students, engineers and researchers in Multiple Branches like ECE, EEE, CSE, Mechanical, Civil with 100% output.Matlab Code for B.E, B.Tech,M.E,M.Tech, Ph.D. Scholars with 100% privacy guaranteed. Get MATLAB projects with source code for your learning and research.
Hi Marco,
I understand that you want to set the “Units Inconsistency messages” as “none” in MATLAB R2017b.
The above can achieved by following the below steps:
- Open “Model Configuration Parameters” from Simulink > Simulation > Model Configuration Parameters or by using the shortcut ctrl + E.
- Go to Diagnostics tab.
- Open Advanced parameters tab below all the solver options if not open already.
- The “Units Inconsistency messages” can be set to “none” here to ignore units warning.
Alternately, you can use the MATLAB command window to set the parameter by using the following command:
set_param('your_model_name', 'UnitsInconsistencyMsg', 'none');
SEE COMPLETE ANSWER CLICK THE LINK
https://www.matlabsolutions.com/resources/how-to-set-to-none-the-unitsinconsistencymsg.php
Comments
Post a Comment